S25N-S50N |
S25V-S50V |
S25P |
S55 |
S60 |
MAC Address |
S25N: 16K
S50N: 32K |
S25N: 16K
S50N: 32K |
16K |
32K |
32K |
IPv4 routes |
4,000 |
4,000 |
4,000 |
16,000 |
16,000 |
IPv6 routes |
2,500 |
2,500 |
2,500 |
8,000 |
8,000 |
Switching fabric capacity |
S25N: 144 Gbps
S50N: 288 Gbps |
S25V: 144 Gbps
S50V: 288 Gbps |
144 Gbps |
192 Gbps |
176 Gbps |
User traffic capacity |
S25N: 128 Gbps (95 Mpps)
S50N: 192 Gbps(144 Mpps) |
S25V: 128 Gbps (95 Mpps)
S50V: 192 Gbps(144 Mpps) |
128 Gbps (95 Mpps) |
144 Mpps |
132 Mpps |
Link aggregation |
8 links per group, 128 groups per stack |
8 links per group, 128 groups per stack |
8 links per group, 128 groups per stack |
8 links per group, 128 groups per stack |
8 links per group, 128 groups per stack |
Stacking capacity |
96 Gbps per stack member |
48 Gbps per stack member |
96 Gbps per stack member |
48 Gbps per stack member |
48 Gbps per stack member |
Queues per port |
4 queues |
4 queues |
4 queues |
4 queues |
4 queues |
VLANs with 4096 tag value support |
1024 |
1024 |
1024 |
1024 |
1024 |
Line-rate Layer 2 switching — All protocols, including IPv4 and IPv6 |
S |
S |
S |
S |
S |
Line-rate Layer 3 routing — IPv4 and IPv6 |
S |
S |
S |
S |
S |
LAG load balancing — Based on Layer 2, IPv4 or IPv6 headers |
S |
S |
S |
S |
S |
Switching latency |
<5 µs for 64 byte frames |
<5 µs for 64 byte frames |
<5 µs for 64 byte frames |
<5 µs for 64 byte frames |
<9 µs for 64 byte frames |
Packet buffer memory |
N/A |
N/A |
N/A |
4MB |
1.25GB |
CPU memory |
N/A |
N/A |
N/A |
2GB |
2GB |
IPv4 host table size |
N/A |
N/A |
N/A |
N/A |
N/A |
IPv6 host table size |
N/A |
N/A |
N/A |
N/A |
N/A |
IPv4 Multicast table size |
N/A |
N/A |
N/A |
N/A |
N/A |
|
S25N-S50N |
S25V-S50V |
S25P |
S55 |
S60 |
Ring stacking topology with dynamic master election |
S |
S |
S |
S |
S |
Dual modular slots with up to four 10 GbE ports |
S |
S |
S |
S |
S |
Link aggregation across stack members |
S |
S |
S |
S |
S |
Built-in power redundancy |
S |
S |
S |
S |
S |
Hot swappable redundant AC or DC power |
N |
N |
N |
S |
S |
Hot swappable redundant fans |
N |
N |
N |
N |
S |
|
S25N-S50N |
S25V-S50V |
S25P |
S55 |
S60 |
Line-rate ports |
S25N: 24 - 10/100/1000 Base-T ports
S50N: 48 - 10/100/1000 Base-T ports |
S25V: 24 - 10/100/1000 Base-T ports
S50V: 48 line-rate 10/100/1000 Base-T ports |
24 ports supporting GbE or 100 Base-FX SFPs |
44 - 10/100/1000 Base-T ports |
44 RJ45 10/100/1000 Base-T ports |
SFP Ports |
4 (shared) |
4 (shared) |
4-ports 10/100/1000 Base-T (shared with SFP ports) |
4 |
4 |
1 RJ45 console/management port with RS232 signaling |
S |
S |
S |
S |
S |
1 RJ45 Ethernet management port |
N |
N |
N |
N |
N |
USB Ports |
N |
N |
N |
2 USB 2.0 ports (1 USB A, 1 USB B) |
2 USB 2.0 ports (1 USB A, 1 USB B) |
2 line-rate ports 10 Gigabit Ethernet XFP |
S |
S |
S |
N |
N |
2 line-rate ports 10 Gigabit Ethernet CX4 |
S |
S |
S |
N |
N |
2 line-rate ports 12 Gigabit Stacking |
S |
S |
S |
S |
N |
2 line-rate ports 10 Gigabit Ethernet SFP+ |
N |
N |
N |
S |
S |
1 line-rate port 24 Gigabit Stacking |
S |
S |
S |
N |
S |
|
S25N-S50N |
S25V-S50V |
S25P |
S55 |
S60 |
Size |
1 RU, 1.7 h x 17.32 w x 16.73" d (4.3 h x 44 w x 42.5 cm d) |
1 RU, 1.7 h x 17.32 w x 16.73" d (4.3 h x 44 w x 42.5 cm d) |
1 RU, 1.7 h x 17.32 w x 16.73" d (4.3 h x 44 w x 42.5 cm d) |
1 RU, 1.7 h x 17.32 w x 18.06" d (4.3 h x 44 w x 45.87 cm d) |
1 RU, 1.7 h x 17.32 w x 20.5" d (4.3 h x 44 w x 52.07 cm d) |
Weight |
14.39 lbs (6.54 kg) |
15.62 lbs (7.10 kg) |
14.43 lbs (6.56 kg) |
14.39 lbs (6.54 kg) |
14.39 lbs (6.54 kg) |
ISO 7779 A-weighted sound pressure level |
S25N: 42.0 dBA at 73.4°F (23°C)/S50N: 59.6 dBA at 73.4°F (23°C) |
S25V: 42.9 dBA at 73.4°F (23°C)/S50V: 62.2 dBA at 73.4°F (23°C) |
45.1 dBA at 73.4°F (23°C) |
59.6 dBA at 73.4°F (23°C) |
59.6 dBA at 73.4°F (23°C) |
|
S25N-S50N |
S25V-S50V |
S25P |
S55 |
S60 |
Operating temperature:
32° to 122°F (0° to 50°C) |
S |
S |
S |
S |
S |
Operating humidity:
10 to 85% (RH), noncondensing |
S |
S |
S |
S |
S |
Storage temperature:
–40° to 158°F (–40° to 70°C) |
S |
S |
S |
S |
S |
Storage humidity:
5 to 95% (RH), noncondensing |
S |
S |
S |
S |
S |
|
S25N-S50N |
S25V-S50V |
S25P |
S55 |
S60 |
Power supply |
100–240 VAC 50/60 Hz, –44 to -60 VDC |
100–240 VAC 50/60 Hz, –48 VDC |
100-240 VAC 50/60 Hz, -44 to -60 VDC |
100–240 VAC 50/60 Hz, –44 to -60 VDC |
100–240 VAC 50/60 Hz, –44 to -60 VDC |
Max. thermal output: |
S25N: 349 BTU/h
S50N (AC): 531 BTU/h,/DC): 465 BTU/h |
S25V: 349 BTU/h
S50V: 497 BTU/h |
(AC): 305 BTU/h
(DC): 262 BTU/h |
443 BTU/h |
531 BTU/h |
Max. current draw per system |
2 A at 100/120 VAC1 A at 200/240 VAC 3.6 A at -48 VDC |
6.5 A at 100/120 VAC3.25 A at 200/240 VAC 11.5 A at -48 VDC |
2 A at 100/120 VAC 1 A at 200/240 VAC, 3.6 A at -48 VDC |
2 A at 100/120 VAC, 1 A at 200/240 VAC, 3.6 A at -48 VDC |
2 A at 100/120 VAC, 1 A at 200/240 VAC, 3.6 A at -48 VDC |
Max. power consumption |
S25N: 102 W, S50N (AC): 156 W, S50N (DC): 136 W |
S25V: 102 W, S50V: 146 W |
S25P (AC): 90 W, S25P (DC): 77 W |
130 W |
N |
Max. PoE power |
N |
320 W using either AC or DC inputs/790 W using load sharing AC and DC inputs |
N |
N |
N |
Reliability |
S25N: MTBF 141,275 hours S50N (DC): MTBF 168,259 hours S50N (AC): MTBF 169,315 hours |
S25V: MTBF 107,720 hours S50V: MTBF 130,482 hours |
S25P (AC): MTBF 164,358 hours S25P (DC): MTBF 164,358 hours |
MTBF 169,315 hours |
MTBF 169,315 hours |
|
S25N-S50N |
S25V-S50V |
S25P |
S55 |
S60 |
EN 60825-1 Safety of Laser Products Part 1: Equipment |
S |
S |
S |
S |
S |
EN 60825-2 Safety of Laser Products Part 2: Safety of |
S |
S |
S |
S |
S |
EN 60950-1, Second Edition |
S |
S |
S |
S |
S |
Equipment Classification Requirements and User's Guide |
N |
N |
N |
N |
N |
FDA Regulation 21 CFR 1040.10 and 1040.11 |
S |
S |
S |
S |
S |
IEC 60950-1, Second Edition Including all National |
S |
S |
S |
S |
S |
Optical Fibre Communication Systems |
N |
N |
N |
N |
N |
UL/CSA 60950-1, Second Edition |
S |
S |
S |
S |
S |
|
S25N-S50N |
S25V-S50V |
S25P |
S55 |
S60 |
Australia/New Zealand: AS/NZS CISPR 22: 2006, Class A |
S |
S |
S |
S |
S |
Canada: ICES-003, Issue-4, Class A |
S |
S |
S |
S |
S |
Europe: EN 55022: 2006 (CISPR 22: 2006), Class A |
S |
S |
S |
S |
S |
Japan: VCCI V3/2007.04 Class A |
S |
S |
S |
S |
S |
USA: FCC CFR 47 Part 15, Subpart B, Class A |
S |
S |
S |
S |
S |
|
S25N-S50N |
S25V-S50V |
S25P |
S55 |
S60 |
EN 300 386 V1.3.3: 2005 for Network Equipment |
S |
S |
S |
S |
S |
EN 55024: 1998 + A1: 2001 + A2: 2003 |
S |
S |
S |
S |
S |
EN 61000-3-2: Harmonic Current Emissions |
S |
S |
S |
S |
S |
EN 61000-3-3:Voltage Fluctuations and Flicker |
S |
S |
S |
S |
S |
EN 61000-4-2: ESD |
S |
S |
S |
S |
S |
EN 61000-4-3: Radiated Immunity |
S |
S |
S |
S |
S |
EN 61000-4-4: EFT |
S |
S |
S |
S |
S |
EN 61000-4-5: Surge |
S |
S |
S |
S |
S |
EN 61000-4-6: Low Frequency Conducted Immunity |
S |
N |
S |
S |
S |
|
S25N-S50N |
S25V-S50V |
S25P |
S55 |
S60 |
All S Series components are EU RoHS compliant. |
S |
S |
S |
S |
S |